Поделиться:
Model No. | YSG-100-24 | |
Configuration | ||
Input Electrical Characteristics Overview | ||
Input voltage range | 90Vac to 264Vac | |
Normal voltage range | 100Vac to 240Vac | |
Freguency range | 50Hz/60Hz±5% | |
Max input ac current | 1.0Amax at full load condition | |
Inrush current (cold start) | 50Atyp peak 120Vac;100 Atyp 220Vac | |
Efficiency(full load) | 90% | |
Harmonic current | Meet GB17625.1-1998/IEC61000-3-2 class D | |
Leakage current | Less Than 0.75mA 230Vac input | |
Standby Power Loss | ≤ 1W Output Power ≤ 0.3W | |
Input Fuse | T3.15A/250Vac | |
Ripple & Noise(Max) | 150mVp-p | |
Output Electrical Characteristics Overview | ||
Output Voltage Current&Regulation | ||
Output Voltage | 5V/12V/+24V | |
Regulation | 5V/12V/+24±5% | |
Rated current | 20A/8.3A/4.2A | |
Voltage Tolerance Limit | 5V/12V/+24 ±10% | |
Slew Rate | 0.2/uS | |
LoadChange | Min. to 50% load and 50% to Max load | |
Note: Transient response measurement shall be made with a load changing repetition rate of 50Hz to 10kHz. | ||
DC Output Hold-Up Time &Full load. | 120Vac input ≥10mS ; 220Vac input ≥10mS | |
DC Output voltage rise time | 120Vac input & Full Load ≤50mS;220Vac input ≤50mS | |
Note: The output voltages shall rise from10% to 90% of their output voltage. | ||
Protection | ||
Protection | DC output Over Voltage Protection | |
DC output Over current Protection | ||
DC Output Short Circuit protection | ||
Environmental Requirement | ||
Temperature | Operating: -10℃ to +50℃; Store: -20℃ to +80℃ | |
Dimension | Product Size 129*97*30mm | |
Packing Size 13*10*3.5 cm | ||
Weight | N.G:0.3KG; G.W: 0.4KG |